Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2003 | PLUMBING - PROGRESS | Approved | IVRS - Inspection 0000*1.) VACUUM TEST FOR M-H" 3,5,6 IS OK 2.) CUT SHEETS FOR VERIFICATION OF GRADE HAS BEEN COMPLETED & SUBMITTED. |
|
| 01/21/2003 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*VACUUM TEST ON M-H #7 OK 6' 7" VACUUM TEST ON M-H #4 OK 6'0" VACUUM TEST ON M-H #5 NOT READY |
|
| 01/16/2003 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*VACCUM TEST FOR M.H. #1 AND M.H. #2 IS OK. |
|
| 12/04/2002 | PLUMBING - PROGRESS | Partial Approval | PLUMBING PROGRESS PRIVATE SEWER 1.) REVIEW 103.5.4.2 94UPC "IT IS THE DUTY OF THE HOLDER OF THE PERMIT TO INSURE THAT THE WORK WILL STAND THE TEST PRESCRIBED BEFORE GIVING NOTIFICATION. 2.) PLEASE HAVE WORK UNDER TEST INSPECTOR ARRIVES. 3.) PLEASE POST YOUR ADDRESS ON THE STREET LISTED. 4.) MANHOLE #3 MANHOLE #4 OK OK TO COVER #5 AIR TEST OK 5.) WILL REQUIRE VERIFICATION OF GRADE BEFORE FINAL. 6.) INSTALL PIPE SO LISTING IS VISIBLE 7.) PIPING TO LAY ON FIRM BED BRIDGING NOT PERMITTED. 8.) SEWER BETWEEN #5 & #4 OK #5 PRESSURE TEST OK OK TO COVER. 9.) SUBJECT TO VERIFICATION OF GRADE. |
|
| 11/18/2002 | PLUMBING - PROGRESS | Partial Approval | AS NOTED ON PLAN PAGES S1 & S2. | |
| 11/14/2002 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection 0000* | |
| 11/13/2002 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* | |
| 10/11/2002 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* |