Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02PL00984

Parcel: 13631024B


Addresses:

4880 S HOUGHTON RD

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
01/23/2003 PLUMBING - PROGRESS Approved IVRS - Inspection 0000*1.) VACUUM TEST FOR M-H" 3,5,6 IS OK
2.) CUT SHEETS FOR VERIFICATION OF GRADE HAS BEEN COMPLETED & SUBMITTED.
01/21/2003 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*VACUUM TEST ON M-H #7 OK 6' 7"
VACUUM TEST ON M-H #4 OK 6'0"
VACUUM TEST ON M-H #5 NOT READY
01/16/2003 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*VACCUM TEST FOR M.H. #1
AND M.H. #2 IS OK.
12/04/2002 PLUMBING - PROGRESS Partial Approval PLUMBING PROGRESS PRIVATE SEWER
1.) REVIEW 103.5.4.2 94UPC "IT IS THE DUTY OF THE HOLDER OF THE PERMIT TO INSURE THAT THE WORK WILL STAND THE TEST PRESCRIBED BEFORE GIVING NOTIFICATION.
2.) PLEASE HAVE WORK UNDER TEST INSPECTOR ARRIVES.
3.) PLEASE POST YOUR ADDRESS ON THE STREET LISTED.
4.) MANHOLE #3 MANHOLE #4 OK OK TO COVER #5 AIR TEST OK
5.) WILL REQUIRE VERIFICATION OF GRADE BEFORE FINAL.
6.) INSTALL PIPE SO LISTING IS VISIBLE
7.) PIPING TO LAY ON FIRM BED BRIDGING NOT PERMITTED.
8.) SEWER BETWEEN #5 & #4 OK #5 PRESSURE TEST OK OK TO COVER.
9.) SUBJECT TO VERIFICATION OF GRADE.
11/18/2002 PLUMBING - PROGRESS Partial Approval AS NOTED ON PLAN PAGES S1 & S2.
11/14/2002 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection 0000*
11/13/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*
10/11/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*