Permit: T02PL00972

Parcel: 135063560


Addresses:

6909 E CALLE PEGASO

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/21/2002 PLUMBING - FINAL Approved 1.) THIS INSPECTION APPROVED 5/20/02
05/20/2002 PLUMBING - FINAL Partial Approval 1.) PERMIT SECURED FOR GAS AND WATER HEATER 2.) PRESSURE TEST OK UNDERGROUND PIPING OK ROOF TOP PIPING OK OK TO BACKFILL. 3.) WATER HEATER OK 4.) SEE NOTE #4 5/17/02 NEED TO INSPECT ALL GAS FIRED APPLIANCES 5.) REINSPECTED 1:30 PM 6.) STOVE AND FURANCE OK 7.) OK FOR GAS. 8.) UCC LEFT AT METER.
05/17/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) CAN NOT HAVE A FLEX LINE IN P & T DRAIN 2.) MUST SCREW DOWN FLU VENT FOR WATER HTR WITH (3) SHEET METAL SCREWS PER JOINT AND VENT CONNNECTOR 3.) CAN NOT HAVE GAS LINE UNDERGROUND UNDER THE PORCH. THE PORCH IS CONSIDERED PART OF THE STRUCTURE SEE 1211.3 SECTION IN THE 94 UPC. 4.) MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING. 5.) RE TEST SYSTEM.
05/16/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION.