Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/17/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) WATER HTR FLU VENT CAP P & T VALVE & DRAIN IS OK 4.) FURANCE FLU VENT IS OK 5.) OK TO BACKFILL TRENCH.
05/09/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) MUST SCREW DOWN WATER HTR FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT @ COLLAR & FLU VENT. 2.) CAN NOT HAVE FLEX LINE IN P & T DRAIN. 3.) IT APPEAR THAT GAS LINE BY METER & FENCE DOES NOT MEET THE MIN DEPTH OF 18"