Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/27/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 05/20/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED PROPER CLEARANCE AROUND VENT PIPE 1" MINIMUM FOR DOUBLE WALL VENT 6" MINIMUM FOR SINGLE WALL VENT 2) TPRV DISCHARGE LINE MUST GO TO OUTSIDE OF BUILDING CALL 791-5550, ASK FOR DAVE MANN REGARDING DISCHARGE LINE |
| 05/16/2002 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) PROVIDE APPROVED ROOF JACK FLASHING ON ALL PENATRATION. 2. APPROVED FLASHING ON VENT AT WATER HEATER PROPER CLEARANCE FOR SINGLE WALL 3.) RELIEF LINE TO BE RUN OUT SIDE BLDG. 4.) APPROVED LISTED VALVES REQUIRED AT EACH FIXTURE 5.) WALL HEATER HAVE BEEN ABANDON. |
| 05/15/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) INSTALL BLOCKING AND PIPE CLAMPS UNDER PIPING ACROSS ROOF 2) INSTALL 3 SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING |