Permit: T02PL00924

Parcel: 11502123B


Addresses:

316 E LESTER ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/27/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
05/20/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) NEED PROPER CLEARANCE AROUND VENT PIPE 1" MINIMUM FOR DOUBLE WALL VENT 6" MINIMUM FOR SINGLE WALL VENT 2) TPRV DISCHARGE LINE MUST GO TO OUTSIDE OF BUILDING CALL 791-5550, ASK FOR DAVE MANN REGARDING DISCHARGE LINE
05/16/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) PROVIDE APPROVED ROOF JACK FLASHING ON ALL PENATRATION. 2. APPROVED FLASHING ON VENT AT WATER HEATER PROPER CLEARANCE FOR SINGLE WALL 3.) RELIEF LINE TO BE RUN OUT SIDE BLDG. 4.) APPROVED LISTED VALVES REQUIRED AT EACH FIXTURE 5.) WALL HEATER HAVE BEEN ABANDON.
05/15/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) INSTALL BLOCKING AND PIPE CLAMPS UNDER PIPING ACROSS ROOF 2) INSTALL 3 SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING