Permit: T02PL00898

Parcel: 121012080


Addresses:

5961 E LINDEN PL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/03/2002 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
05/01/2002 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) MUST REMOVE THREAD PROTECTOR UNDERGROUND AND REPLACE WITH APPROVED COUPLING 2.) MUST TAPE & PRIMER FITTING AND RETEST SYSTEM 3.) MUST USE APPROVED TEST GAUGE FOR GAS LINE WITH A GAUGE WITH 1/10 INCREMENTS. 4.) MUST USE APPROVAL FLASHINGS ON ALL ROOF PEENETRATIONS 5.) WATER HTR FLU VENT IS WITHIN 10' OF COOLER THEN FLU VENT MUST EXTEND 1'-0" ABOVE COOLER. 6.) MUST REPLACE P & T DRAIN LINE THIS P & T DRAIN UP THRU ROOF IS A EXSISTING SYSTEM. 7.) REMOVE 3/4" TEE W/CAP OR COMPLETE GAS LINE TO FUTURE RANGE.