Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 05/03/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 05/01/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*1.) MUST REMOVE THREAD PROTECTOR UNDERGROUND AND REPLACE WITH APPROVED COUPLING 2.) MUST TAPE & PRIMER FITTING AND RETEST SYSTEM 3.) MUST USE APPROVED TEST GAUGE FOR GAS LINE WITH A GAUGE WITH 1/10 INCREMENTS. 4.) MUST USE APPROVAL FLASHINGS ON ALL ROOF PEENETRATIONS 5.) WATER HTR FLU VENT IS WITHIN 10' OF COOLER THEN FLU VENT MUST EXTEND 1'-0" ABOVE COOLER. 6.) MUST REPLACE P & T DRAIN LINE THIS P & T DRAIN UP THRU ROOF IS A EXSISTING SYSTEM. 7.) REMOVE 3/4" TEE W/CAP OR COMPLETE GAS LINE TO FUTURE RANGE. |