Permit: T02PL00871

Parcel: 106051190

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02PL00871

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
04/29/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SEE 608.5 94UPC T & P RELIEF TERMINATION 2.) SEE 510.6 94UPC WATER HEATER SUPPORT 3.) SEE 517.3 VENT TERMINATION 4.) WATER HEATER NOT LEVEL CLEARANCES NOT MAINTAINED 5.) ENCLOSURE NOT SECURE 6.) NO TOP ON ENCLOSURE 7.) INSTALL VACUUM BREAKER ON HOSE BIBB.
04/25/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) CHANGE GALVANIZED 3/4 NIPPLES TO BRASS 2) INSTALL GALVANIZED 3/4 90 ON END OF TPRV DISCHARGE LINE 3) PROVIDE 1" MINIMUM CLEARANCE AROUND VENT PIPING