Permit: T02PL00830

Parcel: 135051710


Addresses:

6622 E CALLE LUNA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/25/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) METER RELOCATE 1 1/4" SCOTCHCOAT TO NEW METER LOCATION OK PRESSURE TEST OK CONNECTION OK 2.) OK FOR GAS 3.) UCC LEFT AT METER.
04/23/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) WHERE PIPING MEETS, THE CONNECTION SHALL BE MADE WITH A RIGHT-LEFT NIPPLE AND COUPLING. A GROUND JOINT UNION MAY BE USED AS AN APPLIANCE CONNECTOR OR IN AN EXPOSED EXTERIOR LOCATION WHEN PRECESSED BY AN APPROVED BLDG SHUT OFF VALVE FOR INSPECTION 740-6970.