Permit: T02PL00803

Parcel: 120084340


Addresses:

256 W OKLAHOMA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/22/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR GAS 3.) OK TO BACKFILL 4.) UCC LEFT AT METER.
04/19/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) WHERE PIPING MEETS, THE CONNECTION SHALL BE MADE WITH A RIGHT LEFT NIPPLE AN COUPLING UNIONS NOT ALLOWED. 2.) COMBUSTION RELIEF IS REQUIRED WITHIN THE UPPER AND LOWER 12" OF THE ENCLOSURE 3.) GAS FLEX AT STOVE OK 4.) T & P RELIEF OK.
04/17/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PRESSURE TEST 10# MINIMUM OK 2.) ALL PIPING LESS THAN 6" ABOVE GRADE TO BE SCOTCH COAT. ALL SCOTCH COAT MARRED BY PIPE WRENCHES TO BE WRAPPED. 3.) ALL UNDERGROUND PIPING REQUIRES 12" OF COVER. 4.) A GAS FLEX MAY NOT PASS THROUGH A PARTITION STOVE. 5.) NO COMBUSTION RELIEF ON WATER HEATER ENCLOSURE 6.) PVC NOT APPROVED FOR T & P RELIEF DRAIN.