Permit: T02PL00769

Parcel: 122091570


Addresses:

4158 E LINDEN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/17/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
05/10/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) DISCHARGE LINE MUST HAVE A MINIMUM OF 1/4" PER FOOT DOWNWARD SLOPE AT ALL POINTS
05/08/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) TPRV DISCHARGE LINE MUST BE HARD DRAWN COPPER 2) TYPE M IS OK USE ANY FITTINGS 45 DEGREES ETC.
05/05/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) NEED SEPARATE PERMIT FOR WATER HEATER INSTALLATION 2) WHEN PERMIT IS OBTAINED: A) FLEX PIPING CANNOT BE USED ON WATER HEATER TPRV DISCHARGE LINE B) NEED 3 SCREWS TO SECURE THE SECTIONS OF VENT PIPE C) UNKINK HOT WATER FLEX LINE 3) WHEN COMPLETED GAS FINAL WILL BE APPROVED