Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/11/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*ALL CORRECTION HAVE BEEN MADE. |
| 04/05/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) GAS PRESSURE TEST WAS BELOW 10LBS MIN. 2.) WATER HTR FLU VENT MUST BE SCREWED DOWN WITH (3) SHEET METAL SCREWS PER JOINT AND @ VENT CONNECTOR. 3.) WE HAVE NO RECORD OF EXSISTING P & T DRAIN INSTALLATION GOING UP THROUGH ROOF. IF NO DOCUMENTATION CAN BE PROVIDED THEN P & T DRAIN MUST GO TO DAYLIGHT WITH GRAVITY FLOW OR TO APPROVED RECEPTOR. 4.) WATER HTR FLU VENT MUST EXTEND 1'-0" ABOVE COOLER WHEN FLU VENT IS LOCATED WITHIN 10'-O" OF INTAKE OF COOLER. |