Permit: T02PL00721

Parcel: 132081220


Addresses:

2303 E PARKSIDE DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/20/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER.
05/06/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*/ 1) VENT PIPE MUST BE SECURED TO THE VENT CONNECTOR AND EACH JOINT WITH 3 SCREWS THEN TAPED
04/19/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SECURE A PERMIT FOR THE NEW WATER HEATER EXTEND T & P RELIEF TO OUTSIDE. 2.) ALL VALVES TO BE AGA OR CSA APPROVED. 3.) PRESSURE TEST OK 4.) MAKE SURE RISER AT METER IS VERTICAL AND DOESNT LEAK.