Permit: T02PL00708

Parcel: 125120050


Addresses:

3447 E BUNELL ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/02/2002 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000* 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENT, P & T DRAIN & VALVE IS OK 4.) FURNACE IS OK.
04/01/2002 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) CAN NOT HAVE ANY FLEX CONNECTOR PENETRATE CABINET WALL. MUST HARD PIPE GAS LINE THROUGH CABINET WALL THEN CONNECT SHUT OFF VALVE & FLEX. 2.) MUST COMPLETE 1/2" GAS LINE @ WATER HTR AND RE TEST SYSTEM TO 10LBS MIN.