Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T02PL00687

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
04/01/2002 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
03/28/2002 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*ENTER BACKYARD THRU EAST SIDE GATE. METER IN BACK. 1.) REMOVE UNION FROM THE GAS LINEON THE ROOF. USE REVERSE THREAD COUPLINGS & NIPPLES. YOU CAN HAVE A UNION AT THE APPLIANCE IMMEDIATELY PRECEDED BY A SHUT OFF VALVE MUST BE WITHIN 3' OF HTE APPLIANCE. 3.) WATER HEATER ON SIDE OF HOUSE NEEDS A T & P DRAIN LINE. 4.) SYSTEM NOT HOLDING PRESSURE.
03/26/2002 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*