Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/22/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES ARE OK 3.) NOTE: GAS METER IS TO BE RELOCATED BY S.W. GAS GAS, METER IS STILL ENERGIZED. |
| 05/20/2002 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*1.) OK TO COVER GAS LINE TRENCH. 2.) CAN NOT HAVE A UNION IN GAS LINE. WHERE A UNION IS NEEDED YOU MUST USE A RIGHT & LEFT HAND NIPPLE. 3.) REMOVE THREAD PROTECTOR IN GAS LINE & REPLACE WITH APPROVED COUPLING. 4.) RE TEST SYSTEM. |