Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02PL00626
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* 889-1888 | |
03/19/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) MUST REMOVE ASBESTOS FLU VENT AND REPLACE WITH DBL WALL FLU VENT & CAP. 2.) MUST USE PROPER TEST GAUGE REQUIRED FOR SYSTEMS REQUIRING 10LBS OR LESS SEE SECTION 712.4.1 94 UPC 3.) P & T DRAIN MUST GO TO DAY LIGHT OR APPROVED RECEPTOR SEE SECTION 608.5 94 UPC. |