Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 03/18/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*1.) MUST USE APPROVED COUPLING IN UNDER GROUND GAS LINE. THREAD PROTECTOR IS NOT A APPROVED COUPLING. 2.) MUST APPLY APPROVED TAPE PRIMER ON ALL APPROVED TAPE PRIMER ON ALL JOINTS UNDERGROUND THEN APPLY 10MIL TAPE 3.) CAN NOT HAVE FLEX LINE IN P & T DRAIN 4.) MUST HAVE 1" CLEARANCE AROUND DBL WALL FLU VENT @ CEILING. 5.) MUST SCREW DOWN DBL WALL FLU VENT WITH (3) SHEET METAL SCREW @ VENT CONNECTOR. 6.) MUST USE TEST GAUGE THAT HAS INCREMENTS OF 1/10 SEE SECTION 712.4.1 94 UPC. |