Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02PL00402

Parcel: 138102020


Addresses:

5933 S 6TH AV


Inspection Status: Partial Approval

Inspection History: PLUMBING - PROGRESS

Permit Number - T02PL00402

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Partial Approval

Date Description Inspector Results Comments
03/27/2002 PLUMBING - PROGRESS Partial Approval 1.) 8" DIP FROM BLDG #5A TO MANHOLE NUMBER 4 OK WATER TEST OK 2.) 8" SDR 35 FROM BLDG 7A TO MANHOLE #3 OK WATER TEST OK 3.) 6" SDR FROM #10 A TO MANHOLE #2 OK WATER TEST OK.
03/22/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*1.) 8" SDR 35 FROM MANHOLE 2 TO MANHOLE 4 OK FIRST 200' SDR LAST 90' DIP. 2.) 6" DIP AT BLDG 6A BLDG DRAIN TO MAIN OK TRANSITION FITTINGOK 3.) 8" SDR 35 FROM MANHOLE #2 TO MANHOLE #3 OK 4.) 6" SDR 35 FROM BLDG 8A TO MANHOLE #3 OK. 5.) 6" SDR 35 FROM BLDG 9A TO MANHOLE #3 OK 6.) WILL TEST AT A LATER DATE.
03/15/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*FROM M-H #1 APROX 87' WEST OF M-H #1 TEST OK M-H OK OK TO BACKFILL.
03/11/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*MANHOLE BASES #5,#6,#7, OK.
03/07/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000*
03/06/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000* 1.) 6" SDR 35 FROM MANHOLE SIX TO MANHOLE SEVEN OK 2.) WATER TEST OK 3.) BLDG SEWER FROM BLDG #1 TO MANHOLE #6 OK 4.) OK TO BACKFILL THESE AREAS.
03/05/2002 PLUMBING - PROGRESS Partial Approval IVRS - Inspection 0000$ 1.) 8" SDR 35 FROM MANHOLE #7 TO MANHOLE #6 OK 6" SDR 35 SEWER FROM BLDG #4 TO MANHOLE #6 OK TIE IN TO BLDG DRAIN AT BLDG #4 OK TRANSITION FITTING OK WATER TEST OK 2.) OK TO BACKFILL THESE AREAS.
02/28/2002 PLUMBING - PROGRESS Partial Approval 1.) SDR35 AND DUCTILE IRON FROM MANHOLE IN S 6TH AV TO MANHOLE #7 OK 2.) WATER TEST OK 3.) OK TO BACKFILL.