Permit: T02PL00323

Parcel: 112051330

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T02PL00323

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2002 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection 0000*1.) TRANSITION FROM PVC TO GALVANIZED OK 2.) REPAIR COUPLING OK 3.) PRESSURE TEST OK 4.) OK TO COVER.
02/11/2002 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection 0999*1.) REPLACE SCH 40 PVC M/ADPT WITH SCH 80 M/ADPT OR SCH 80 NIPPLE. BE SURE AND USE APPROVED SOLVENT CEMENT FOR SCH 80 FITTINGS.