Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/13/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER. |
| 02/12/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) SEE NOTE #3 ABOVE A GROUND JOINT UNION IN THE LOCATION NEAR THE WATER HEATER DOOR IS NOT APPROVED. 1.) WHERE PIPING MEETS THE CONNECTION SHALL BE MADE WITH A RIGHT LEFT NIPPLE AND COUPLING. A UNION MAY BE USED I AN EXTERIOR EXPOSED LOCATION WHEN PRECEEDED BY A BLDG SHUT OFF VALVE. 2.) T & P RELIEF DRAIN MUST BE FULL SIZE 3/4" IPS APPROVED MAT'S CPVC COPPER GALVANIZED |
| 02/05/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* |