Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 02/13/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 02/12/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999* |
| 02/05/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*1.) NO PRESSURE TEST. MUST HOLD 10# TEST 2.) 90 ELL AT BLDG REQUIRES 10MIL TAPE COVERING FITTING 3.) WHERE PIPING MEETS,C CONNECTION SHALL BE MADE WITH RIGHT LEFT NIPPLE AND COUPLING 4.) ALL VALVES TO BE AGA OR CSA APPROVED. 5.) T & P RELIEF DRAIN TO TERMINATE IN APPROVED LOCATION 6.) NO COMBUSTION RELIEF IN FURNACE/WATER HEATER ROOM 7.) DUCT TAPE AND ALUMINUM FOIL NOT APPROVED ON FLUE PIPING. |