Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02PL00138
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/31/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ONE PIECE TRANSITION RISERS OK 2.) TRACER WIRE OK 3.) ENCLOSURE OK 4.) FLUE PIPING OK 5.) CLEARANCE OK 6.) ALL CORRECTIONS MADE OK 7.) UCC LEFT AT METER 8.) OK TO BACKFILL. SW GAS 889-1888. | |
| 01/28/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) REVIEW REQUIREMENTS FOR VENT CONNECTOR, AND OR VENT FOR WATER HEATER (CLEARANCES) 2.) SUPPORT THE WATER HEATER ENCLOSURE 3.)VERIFY NUMBER EIGHTTEEN TRACER WIRE. | |
| 01/25/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) REVIEW 1211.3 9 UPC NO BLK PIPE UNDERGROUND 2.) REVIEW 1211.5 RISERS CONNECTING TO PLASTIC PIPE 3.) SUPPORT WATER HEATER ENCLOSURE. 4.) TRANSITION UNDERGROUND AT BLDG COVERED. 5.) VENTING FOR EXISTING WALL FURNACE INCOMPLETE 6.) SUPPORT PIPING ON EXTERIOR WALL 7.) REVIEW 1211.16 COPPER TRACER WIRE W/PLASTIC PIPE. 8.) INSTALL APPROVED FLASHINGS WHERE PASSING THROUGH ROOF. |