Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02PL00138

Parcel: 122120640


Addresses:

1231 N BELVEDERE AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02PL00138

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/31/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) ONE PIECE TRANSITION RISERS OK 2.) TRACER WIRE OK 3.) ENCLOSURE OK 4.) FLUE PIPING OK 5.) CLEARANCE OK 6.) ALL CORRECTIONS MADE OK 7.) UCC LEFT AT METER 8.) OK TO BACKFILL. SW GAS 889-1888.
01/28/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) REVIEW REQUIREMENTS FOR VENT CONNECTOR, AND OR VENT FOR WATER HEATER (CLEARANCES) 2.) SUPPORT THE WATER HEATER ENCLOSURE 3.)VERIFY NUMBER EIGHTTEEN TRACER WIRE.
01/25/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) REVIEW 1211.3 9 UPC NO BLK PIPE UNDERGROUND 2.) REVIEW 1211.5 RISERS CONNECTING TO PLASTIC PIPE 3.) SUPPORT WATER HEATER ENCLOSURE. 4.) TRANSITION UNDERGROUND AT BLDG COVERED. 5.) VENTING FOR EXISTING WALL FURNACE INCOMPLETE 6.) SUPPORT PIPING ON EXTERIOR WALL 7.) REVIEW 1211.16 COPPER TRACER WIRE W/PLASTIC PIPE. 8.) INSTALL APPROVED FLASHINGS WHERE PASSING THROUGH ROOF.