Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 01/13/2002 |
PLUMBING - YARD WTR LINE/TEST |
|
Approved |
IVRS - Inspection 0000*1) PVC YARDWATE OK 2.) TRANSITION FITTINGS OK 3.) OK TO COVER. |
| 01/10/2002 |
PLUMBING - YARD WTR LINE/TEST |
|
Denied |
IVRS - Inspection 0999* |
| 01/09/2002 |
PLUMBING - YARD WTR LINE/TEST |
|
Not ready for Inspection |
IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION 2.) SEE 606.2.2. 94 UPC FEMALE PVC SCREWED FITTINGS FOR WATER PIPING ARE PROHIBITED 3.) SEE 609.1 MINIMUM COVER SHALL BE TWELVE INCHES BELOW FINISH GRADE. 4.) SEE 602.3 VACUUM BREAKERS REQUIRED ON ALL HOSE BIBBS. 5.) SEE I.S. 301.1.3 IDENTIFYING MARKINGS SHALL BE VISIBLE WITHOUT MOVING MAT'LS. |