Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T02PL00031
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/15/2002 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000*1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENT, P & T DRAIN & VALVE IS OK 4.) WALL FURNACE FLU VENT IS OK. | |
01/14/2002 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999*1.) MUST HAVE ACCESS TO ALL GAS APPLIANCES IN UNITS 2.) MUST STRAP DOWN EVERY 6' GAS LINE TO WALL FURANCE IN CENTER UNIT 3.) MSUT STRAP 1/2" DROP FOR WATER HTR @ REAR UNIT 4.) MUST HAVE SINGLE WALL FLU VENT REMOVED FROM DBL WALL FLU VENT AND EXTEND WITH DBL WALL ABOVE WALL WITH CAP 5.) OK TO BACKFILL TRENCH. | |
01/09/2002 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999*1.) MUST HAVE A LICENSE PLBG. CONTRACTOR DO ANY WORK ON GAS SYSTEM FOR RENTAL PROPERTY. 2.) CAN NOT HAVE ANY REPAIR COUPLING OR TEES ON ROOF. 3.) CAN NOT HAVE NO UNIONS IN LINE. 4.) MUST BRING ALL GAS APPLIANCES UP TO CODE. 5.) WILL REQUIRE A APPROVED DRAWING ON GAS SYSTEM SHOWING TOTAL DEVELOPED LENGTH AND C F H DEMAND. 6.) MUST BLOCK & STRAP EXSISTING GAS LINE ON ROOF 7.) MUST CONNECT NEW GAS LINE TO EXSISTING 8.) RE TEST SYSTEM. | |
01/08/2002 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999*1.) NOT READY FOR INSPECTION 2.) MUST PROVIDE AIR PRESSUR TEST ON ENTIRE SYSTEM 10LBS MIN. |