Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date |
Description |
Inspector |
Results |
Comments |
| 08/12/2002 |
SIGN ELECTRIC |
|
Approved |
IVRS - Inspection 0000* |
| 08/05/2002 |
SIGN ELECTRIC |
|
Denied |
IVRS - Inspection 0999*1.) REMOVE ENOUGH OF OUTER COATING ON LIQUID TIGHT CONDUIT @ HIGH VOLTAGE SPLICE SO THAT THERE IS A GOOD METAL TO METAL BOND. 2.) SECURE CONDUIT LENGHTS OVER 3 1/2' LONG @ 4' INTERVALS AND WITHIN 12" OF EACH TERMINATION POINT. USE APPROVED CONDUIT CLAMPS. |
| 07/18/2002 |
SIGN ELECTRIC |
|
Not ready for Inspection |
IVRS - Inspection 0000*INSTRUMENTAL MUSIC NEON PLAN CHANNEL DOUBLE BACK THROUGH WALL. |