Inspection Status: Approved
Inspection History: SIGN ELECTRIC
| Date |
Description |
Inspector |
Results |
Comments |
| 05/14/2002 |
SIGN ELECTRIC |
|
Approved |
IVRS - Inspection 0000* |
| 05/06/2002 |
SIGN ELECTRIC |
|
Denied |
IVRS - Inspection 0999*1.) NEC 350-18 SUPPORT FLEXIBLE METAL CONDUIT WITHIN 12" OF EACH TERMINATION AND @ INTERVALS NO GREATER THAN 4 1/2. 2.) NEC 300-11 JUNCTION BOXES MUST BE SECURELY FASTENED IN PLACE. 3.) NEC 350-20 FITTING @ SWITCH BOX NOT INSTALLED PER LISTING (FLEX CONDUIT NIPPLE UNATTACHED). |
| 04/29/2002 |
SIGN ELECTRIC |
|
Not ready for Inspection |
IVRS - Inspection 0000*SIGN E. NOT READY. 1.) CHILDREN REACHING FOR SKY. 2 1/2' X 12' " FLOURSCENT. |