Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02ME00774

Parcel: 119211160


Addresses:

1662 W CIRCLE A DR

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
12/23/2002 MECHANICAL - FINAL Approved IVRS - Inspection 0000*CORRECTION SHOULD BE REMOTE CONDENSER WITH FURN. & EVAP. CASED COIL NOT A ROOF TOP COMB. GAS PACK! COMB AIR OPENING IN LOWER STEM WALL OK.
12/19/2002 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*OPEN COMBUSTION AIR LOWER DUCT AT STEM WALL.
12/16/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
1.) CONDENSER FUSED AT 60AMPS MAX FUSE SIZE, 30 AMPS.
2.) THERM. WIRE EXPOSED TO SUN LIGHT/WEATHER.
3.) FURNACE RM. NO COMBUSTION/RELIEF AIR.
4.) VENT PIPE, 90 ELBOW POPEDENT
5.) MAY NEED TO CHECK CLEARANCE ON FURN. MAY REQUIRE B-1 VENT TO TOP OF FURN. FOR REDUCED CLEARANCE AT FRONT,