Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T02ME00626
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/15/2002 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000* | |
09/25/2002 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000*EAST REAR FURN RM. 1.) PROVIDE CLEARANCE, SINGLE WALL CONN VENT PIPE AND REFRIG. LINE INSUL. 2.) EAST REAR CONDENSER. REMOVE ADDITIONAL WIRING TO LIGHTS CIRCUIT. LEAVE UTILITY RECEPTICLE FOR VACUM PUMP/DRILL USE ONLY. USE OFF SET NIPPLE FOR EXPOSED WIRE. 3.) UNABLE TO OPEN REAR FURN. RM. NORTH SIDE OF BLDG. | |
09/24/2002 | MECHANICAL - FINAL | Denied | 1.) IF YOU WISH TO CONTINUE RECEIVING INSPECTIONS PLEASE POST YOUR ADDRESS. 2.) A TRAP ARM MUST BE AT LEAST TWO PIPE DIAMETERS IN LENGTH FROM THE WEIR OF THE TRAP TO THE POINT OF VENT. 3.) ABS BLDG SEWER MUST HAVE A MINIMUM OF TWELVE INCHES OF COVER 4.) MISSING DIRECTIONAL CLEAN OUT IN BETWEEN UNITS AS SHOWN ON PLAN. 5.) PLEASE EXPOSE ALL FITTINGS FOR INSPECTION. |