Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T02EL02504
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/03/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
12/31/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999* 1.) PLEASE SECURE GROUNDED ELECTRODE CONDUCTOR ACROSS CEMENT 2.) PLEASE VERIFY LISTING FOR GROUND CLAMPS. CAN NOT LOCATE ON CLAMP. 3.) SERVICE COVER TO BE ABLE TO OPEN 90 4.) ALL STRANDS OF CONDUCTOR TO BE UNDER TERMANAL AT BREAKER AND NEUTRAL BAR. 5.) FINISH TERMANATING ALL CONDUCTOR 6.) INSTALL CONDUCTOR AS PER MANUFACTURES INSTRUCTIONS FOR STIPPING DEPTH. |