Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02EL02463

Parcel: 133290270


Addresses:

8502 E VICKSBURG ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T02EL02463

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/03/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 4/3/03 AT 9:15AM OK TO CLEAR.
03/28/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*FINISH ITEMS #3 & 7 OF PREVIOUS INSPECTION.
01/24/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*1.) PLEASE VERIFY LICENSED ELECTRICAL CONTRACTOR. BAKERS MOBILE IS FOR A/C & REFRIGERATION ONLY NOT ELECTRICAL.
2.) WATER BOND TO BE TO INTERIOR PIPING PAST VAVLES AND UNIONS.
3.) PLEASE VERIFY GAS BONDING.
4.) USE AN APPROVED FITTING FOR L.B. CHASE NIPPLE NOT APPROVED.
5.) SUPPORT CONDUIT AS PER CODE BELOW PANEL.
6.) 1/4 MININUM HARDWARE IS REQUIRED FOR RISE SUPPORTS.
7.) INSTALL GROUNDING CONDUCTORS AS PER MANFACTURES LABELS
8.) A BONDING DEVICE IS NEEDED AT JUNCTION BOX ALSO BOND ENCLOUSER.
9.) PLEASE VERIFY PERMIT FOR NEW A/C INSTALLATION.
12/27/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0210*
1.) THE ADDRESS ON THE METER SIDE MUST BE OF DURABLE MATERIAL RESISTANT TO THE WEATHER. USE METALLIC STICK ON OR EMBOSSED METAL STRIP. MAGIC MARKER, PEN, OR PENCIL ARE NOT ACCEPTABLE.
2.) THE NEW SERVICE REQUIRES ALL OF THE FOLLOWING ITEMS.
BE GROUNDED/BONDED TO THE SERVICE:
1.) COLD WATER PIPING WHERE IT ENTERS THE HOUSE.
2.) GAS PIPING WHERE IT ENTERS THE HOUSE.
THE OLD GROUND IS UNPROVEN AND NOT ACCEPTABLE.
3.) A SECOND STRAP IS REQUIRED ON TEH RISER PIPE WITHIN 8" OF THE PANEL.
PLEASE CORRECT ADN RECALL INSPECTION.