Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2002 | ELECTRIC - RECONNECT | Approved | OK TO CLEAR RECONN. | |
| 12/12/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*1.) STORAGE ROOM 220 VOLT OUT LET NEED TO BE PROPERLY WIRED AND FINISHED OFF. 2.) EXTERIOR WIRING WRONG. A.) DOUBLE LUGGING, B) WIRING TO DISCORRECT, C) EXPOSED WIRING BELOW 8FT D.) IMPROPER USEAGE SITTING OF DISCONNECT. 3.) MOVE ONE SMOKE DETECTOR CLOSER TO HALL CENTER 4.) WROUGHT IRON BARS ARE NOT LOCKING AND OPENING QUICKLY AND PROPERLY IN BEDROOMS. 5.) FOR NO'S. 1 AND 2 MUST GET A LICENSED ELECTRICAL CONTRACTOR OR REMOVE COMPLETELY. COMPLETE ALL ITEMS PRIOR TO CALLING FOR INSPECTION OR RE FEE TO BE CHARGED. |
|
| 12/11/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*1.) HOUSE HAS TO BE OPEN FOR INSPECTION. 2.) STORAGE ROOM 220 VOLT OUTLET IS UNWIRED WITH WIRING HANGING OUT OF BOX PROPERLY DEAD END AND COVER OR REMOVE ALSO ALL EXPOSED WIRING TO BE PHYSICALLY PROTECT UP TO 8'. 3.) ELECTRICAL WIRING BY SERVICE AT REAR PORCH INSTALLED WRONG THERE IS DOUBLE LUGGING ON ONE 20 A BREAKER, WIRING TO DISCONNECT BY SERVICE WRONG, ALL WIRING BELOW 8' TO BE IN CONDUIT OR PROTECTED METHOD REMOVE OR CORRECT. |