Permit: T02EL02351

Parcel: 126133100


Addresses:

4509 E MONTECITO ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/28/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
08/13/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) OK 2) THE FEEDERS FOR SEPERATE APARTMENTS HAVE TO BE RUN SEPERATLY - DO NOT RUN THRU THE SAME PANEL. 3) THE CHASE FITTING FROM THE BOTTOM OF SERVICE MUST BE A CLOSED NIPPLE WITH ONE LOCK NUT INSIDE AND ONE LOCKNUT OUTSIDE. 4) FIND AW SCREWS FOR OUTSIDE COVERS ON SERVICE AND PANEL. 5) NOTICE THE HOT LEG INSIDE SUB-PANEL, THE KEARNEY FITTING IS NOT TAPED COMPLETLY, IT IS HOT AND METAL IS EXPOSED. TAPE ALL FITTINGS HEAVIER.
03/05/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*
COMPLETE ALL INSTALLATION AND RECALL ON THE 2 ADDRESS.
ALSO HAVE PERMIT POSTED FOR HOUSE OR GARAGE .