Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2003 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* | |
| 01/28/2003 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection 0000*1.) GROUNDING TO HAVE PROPER TERMANATIONS. LUG HAS MULTIPOLE TERMANATIONS AND A LISTING FOR A SINGLE TERMINATION. ALSO SHEET METAL SCREWS NOT ALLOWED FOR GROUNDING. | |
| 12/20/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* 1.) CONDUCTORS MUST BE SECURED TO 12 X 12 J-BOX TERMINATION. MUST BE PROTECTED IN RACEWAY. ALSO J-BOX TO BE SEALED PROPERLY TO PREVENT WATER FROM RUNNING BEHIND AND INTO STRUCTURE. 110-12 NEC ART 370 NEC. 2.) PVC EXPOSED ON WALL TO BE SCH 80 #9287 CITY ORDIN. 3.) CIRCUIT BREAKERS MUST BE I.D. |