Permit: T02EL02302

Parcel: 136203460


Addresses:

3761 S LE BEAUX PL

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/26/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*
TO APPROVED RECONNECT
1.) EACH BEDROOM MUST BE FILLED WITH A SMOKE DETECTOR THESE MAY BE BATTERY OPERATED. PLEASE MOUNT THEM NOT CLOSER THAN THREE 3' FEET AWAY FROM ANY AIR SUPPLY DUCT/GRILL AND IF WALL MOUNTED THEY SHOULD BE NOT CLOSER THAN 6" TO CEILING BUT NOT LOWER THAN 12". IF CIELING MOUNTED THEY SHOULD BE AT LEAST 16" AWAY FROM ANY CORNER.
2. ) REPLACE LIGHTING FIXTURE IN HALL.
3.) THE METER BOX MUST FIRMLY ATTACHED TO WALL. CHECK OTHER ELECTRIC BOXES FOR PROPER MOUNTING.
4.) RE ATTACH BACK YARD LIGHTS TO PORCH.
5.) REMOVE UNUSED OUTLETS BELOW THE CIRCUIT BREAKER PANEL.
6.) THE CIRCUIT BREAKER PANEL MUST HAVE AN I.D. INDEX OF ALL CIRCUITS.
I SUGGEST YOU HIRE A LICENSED CONTRACTOR.