Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2002 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection 0000*OK TO CLEAR UPGRADE. | |
| 11/06/2002 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0999*1.) THE #4 COPPER GROUND WIRES AT BOTTOM OF 3/4" EMT NEED TO BOND TO END OF CONDUIT. 2.) THE ADDRESS MUST BE OF A PERMANENT TYPE. 3.) VERIFICATION OF ALL #12 CIRCUITS INSIDE NOT DONE. |
|
| 11/01/2002 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection 0999*1.) SLEEVE FOR GROUNDING ELECTRODE CONDUCTOR REQUIRE BONDING FROM CONDUIT TO EACH WIRE ALSO REQUIRE A GROUNDING BUSHING ON TOP. OR REPLACE WITH PVC CONDUIT. 2.) MUST CHECK TO SEE IF ALL OF HOUSE IS IN FACT WIRED WITH #12 WIRE. 3.) MUST HAVE PERMANENT ADDRESS TAG 4.) OK TO BURRY GROUND WIRE PLEASE CORRECT AND RECALL. |