Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*APPROVED PER MCAPISTR INSPECTION NOTES MECH PERMIT FOR NEW FURN. T02ME00007. |
| 11/20/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0215*THE FORCED AIR UNIT EXHAUST PIPE IS SEPARATED FROM THE RISER SECTION. THIS IS VERY DANGEROUS AS TOXIC GAES CAN BE RELEASED INTO THE BEDROOM. THIS UNIT SHOULD NOT HAVE BEEN INSTALLED IN THE BEDROOM SPACE. |
| 10/24/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245* |
| 10/24/2002 |
ELECTRIC - FINAL |
|
Denied |
1) INTALL LIGHT FIXTURES IN BEDROOM AND CEILING WEST OF KITCHEN (MISSING) 2) INSTALL SMOKE DETECTORS EACH BEDROOM NO CLOSER THAN 3' FROM AC REGISTER, 18' AWAY FROM WALLS IF CEILING MTD. BETWEEN 6" -12" DOWN FROM CEILING IF WALL MTD. BATTERY TYPE OK. 3) POOL EQUIPMENT NOT WIRED PROPERLY, OPEN SPLICES AND EXPOSED ROMEX, WATER PIPE USED FOR CONDUIT SLEEVES NOT AN APPROVED WIRING METHOD. 4) FILL IN HOLES IN DEADFRONT OF SERVICE PANEL WHERE MISSING CIRCUIT BREAKERS 5) INSTALL PERMANENT ADDRESS LABEL ON SERVICE 6) REPAIR COOLER BOX, RE-SUPPORT. 7) WORK TO BE DONE BY C-11 LICENSED CONCTRACTOR |