Permit: T02EL01917

Parcel: 126171620

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/29/2002 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP 10/30/02 AT 9:15 AM THIS UNIT IS NOT TO BE USED FOR PERMANENT HOUSING. SHOP USE ONLY.
09/24/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*1.) INSTALL PERMANENT ADDRESS LABEL ON SERVICE ENCLOSURE MUST BE SCREWED OR RIVITED IN PLACE. 2.) I.D. CIRCUIT BREAKERS. 3.) SUPPORT BOX FOR GFI RECEPT. 4.) GROUND RODS MUST BE PLACED MIN 6' APART AND FLUSH WITH EARTH. 5.) VERIFY PERMITS OBTAINED FOR INTERIOR REMODEL. 6.) VERIFY GAS PIPE BONDING. 7.) PLACEMENT LOCATION OF SERVICE FOR STRUCTURE #2 SUBJECT TO TEP APPROVAL CHECK WITH T.E.P. FIELD TECH.