Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T02EL01899
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2002 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection 0000* | |
11/01/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*ACCESS TO POOL FROM DINING AREA ENCLOSURE GATE MUST BE SELF CLOSING ONLY INSTALLED PAD LOCK. FLOURSCENT FIXTUER REWIRED IN GARAGE WRONG!! SINGLE OPEN CONDUCTOR GOING INTO FIXTUER PLEASE OBATIAN A LICENSED C-11 ELETRICAL CONTRACTOR. CALL 791-5550 1136. OR 1323 AND LEAVE NAME OF CONTRACTOR FOR VERIFICATION. A REINSEPCTION FEE IS DUE BEFORE NEXT INSPECTION. | |
10/31/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*FLUORESCENT FIXTURE IN GARAGE ARE IMPROPERLY OPEN SPLICED WIRED. GATE AROUND POOL NOT SELF CLOSING WOOD FENCING AROUND YARD WITH GATES MUST COMPLY W/POOL CODE. | |
10/28/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0920* | |
09/20/2002 | ELECTRIC - RECONNECT | Denied | HAVE RELEASE FROM MINIMUM HOUSING INSPECTOR. 2.) A/C COMPRESSOR FEEDER CONDUIT NOT ATTACHED TO WALL 3.) INSTALL ALL FIXTURE AND COVER PLATER. |