Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*SENT TO TEP ON 10/15/02 AT 9:15AM. |
| 10/03/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*1.) USE LISTED CONNECTORS IN ENCLOSURE FOR ROMEX TERMINATIONS, 110-3 NEC. 2.) EXPOSED ROMEX IN STORE ROOM TO BE IN CONDUIT OR RUN THRU STUDS BEHIND DRYWALL BELOW 8' 110-12,110-3, 90-4. 3.) OLD FUSE BOX NOT LISTED FOR USE AS J-BOX. |
| 09/23/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*NOTES 1.) WHERE IS GAS PIPE BOND. 2.) ADD ADDITIONAL WORK DONE TO PERMIT, NEED TO INSPECT NEW WIRING INTO DWELLING. 3.) NO ANSWER AT DOOR. 4.) A LEAST 3 NEW MULTI WIRE CIRCUITS RUN FROM NEW SERVICE THRU CARPORT INTO ATTIC. |