Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T02EL01856
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2002 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000*OK TO CLEAR RE-CONN UNITS #138,139,140 | |
09/16/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245*NOTE UNIT #140. CLOSET LIGHT FIXTURES NOT WIRED PROPERLY PORCELIN LAMP HOLDER NEEDS BACK BOX SHOULD BE WIRED IN ROMEX NOT LAMP CORD. REPLACE RECEPT, IN BEDROOM UNIT #138. BROKEN MAIN BREAKER AT SERVICE. UNITS MUST BE HABITABLE PRIOR TO RELEASE OF POWER. UNITS HAVE MISSING OR DAMAGED TOILETS, SINKS APPLIANCES, LIGHT FIXTURES, RECEPTS, ETC. MAKE REPAIRS USING LICENSED CONTRS. RECALL WHEN DONE. |