Permit: T02EL01844

Parcel: 106011120


Addresses:

609 E PASTIME RD

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
11/15/2002 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*SENT TEP ON 11/18/02 AT9:15AM. OK TO RECONNECT.
11/13/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0920*
UNIT LOCKED NO ACCESS 11:00 AM.
10/30/2002 ELECTRIC - RECONNECT Partial Approval IVRS - Inspection 0000*
09/17/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0245*REPAIR OR RESUPPORT COOLER BOX ON ROOF. 2.) ROMEX OUTSIDE AT SERVICE TO IN CONDUIT 3.) SPLICES IN WIRING TO BACKPORCH LIGHT TO BE IN APPROVED J-BOX. 4.) REPLACE RECEPT IN LIVING ROOM EAST WALL, 5.) REATTACH COOLER SWITCH IN HALLWAY. 6.) INSTALL COVER PLATE ON RECEPT, AND PROPERLY WIRE WATER HTR IN NORTH BATHROOM. WORK TO BE DONE BY C-11 LICENSED CONTR. 7.) REPAIR LIGHT FIXTURE BY BACK NORTH EAST DOOR. 8.) RE WIRE NORTH EAST ENCLOSED CARPORT TO CODE, EXPOSED AND UNSUPPORTED ROMEX, BOXES. 9.) INSTALL SMOKE DETECTORS IN BEDROOMS.