Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 09/13/2002 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR RE-CONN. CALLED INTO OFFICE 11:20 AM. TEP SHOULD HAVE OK FROM CITY OF TUCSON TO TURN ON BY 2:30 PM TODAY. |
| 09/11/2002 |
ELECTRIC - RECONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/26/2002 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection 0245*1.) REPAIR OR REPLACE LIGHT FIXTURE OVER SINK. 2.) INSTALL PANEL COVER OUTSIDE AT SERVICE. 3.) INSTALL SMOKE DETECTORS IN EACH BEDROOM, NO CLOSER THAN 3' FROM AC REGISTER, IF CEILING MTD. MUST BE 18" FROM CORNERS OR WALLS, IF WALL MTD. MUST BE BETWEEN 6"-12" DOWN FROM CEILING. BATTERY TYPE OK. 4.) INSTALL MIDWEST COOLER BOXES FOR COOLER THAT HAVE CORDS RUN THRU ROOF. |