Permit: T02EL01675

Parcel: 116120380


Addresses:

1222 W ONTARIO ST

Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Date Description Inspector Results Comments
08/22/2002 ELECTRIC - CABLE DROP Approved IVRS - Inspection 0000*
08/21/2002 ELECTRIC - CABLE DROP Partial Approval IVRS - Inspection 0000*A SEALING DEVICE ARE NEEDED FOR ENTRANCES ABOVE THE BUSS 2.) FINISH GROUNDING. A WATER AND GAS BOND WILL BE NEEDED. 3.) A PERMANENT METAL ADDRESS LABEL IS NEEDED. 4.) A CHASE NIPPLE IS NOT AN APPROVED FITTING FOR CONNECTION TO LB. 5.)PLEASE BOND JUNCTION BOX ENCLOUSER. 6.) FINISH SERVICE INSTALLATION.