Permit: T02EL01057

Parcel: 131080200


Addresses:

6051 E 23RD ST

Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Date Description Inspector Results Comments
05/30/2002 ELECTRIC - CABLE DROP Approved IVRS - Inspection 0000*
05/23/2002 ELECTRIC - CABLE DROP Denied CORRECTION REQUIRED; 1.) THE 2" PVC MUST TERMINATE AT THE PANEL. 2.) ROMEXES CANNOT BE GROUPED AND INSTALLED IN THE PVC UNLESS CALCULATIONS FOR TOTAL SPACE AND HEAT ARE SUBMITTED. 3.) THE PROPER FITTINGS MUST BE USED ON THE PVC. CONNECTORS AND LOCKNUTS ETC. 4.) THE GROUNDING MUST INCLUDE COLD WATER AND GAS PIPING. 5.) USE 15AMP CIRCUIT BREAKERS ON #14 WIRE AND 20AMP. C/B'S ON #12 WIRE. 6.) FILL OUT THE CIRCUIT INDEX. INDICATE WHICH AREA, RM, OR APPLIANCE IS BEING SERVED.