Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/16/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR. NOTE TO OWNER ARE YOU AWARE THAT THE DISCONNECT SWITCH TO "APT" DOES NOT HAVE A SWITCH IN IT, ITS ALWAYS BEEN REQUIRED TO HAVE ONE, ITS OWNERS RESPONSIBLITY TO HAVE THIS CORRECTED PLEASE CALL 791-5550. ASK FOR RAY MAJUATE 7-8AM. |
| 05/15/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Not ready for Inspection |
IVRS - Inspection 0000*CALL BACK WHEN FINISHED 1.) SEAL HOLE BOTTOM OF GUTTER. 2. ADDRESS BOTH UNITS 3.) WERE THE SPLIT BOLTS USED IN GUTTER COPPER TO ALUM TYPE? |
| 05/13/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Denied |
IVRS - Inspection 0999*1.) MUST ADDRESS SERVICES (PERMANENT TYPE) 2. )SPLIT BOLT TYPE KEARNEYS MUST BE ALUM & COPPER TYPE WITH SPLITTER BAR TO ISOLATE COPPER. 3.) SPLICES CANNOT BE CONTAINED INSIDE THE WALL THEY MUST BE ACESSIBLE. 4.) GROUNDING SYSTEMS NEED TO BE TIED TOGETHER C-11 ELECTRICAL CONTRACTOR REQUIRED NOT OWNER OCCUPPIED. |