Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date |
Description |
Inspector |
Results |
Comments |
| 09/10/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Approved |
|
| 08/01/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Denied |
IVRS - Inspection 0930* |
| 06/14/2002 |
ELECTRIC - SERVICE UPGRADE |
|
Denied |
IVRS - Inspection 0210*1.) THE GROUNDING OF THE ELECTRIC SERVICE MUST INCLUDE TWO 5/8 X 8' GROUND RODS DRIVEN TO 2" BELOW GROUND LEVEL AND SET NOT CLOSER THAN 6' FT APART. A # 6 BARE (SOLID) COPPER CONDUCTOR SHOULD BE USED TO CONNECT THESE TO THE PANEL. 2. LEAVE A COPY OF THE PERMIT BUILDING PERMIT FOR THE WORK OF ENCLOSING THE REAR PORCH. THANKS FLAG THE GROUND RODS FOR EASY LOCATION AT INSPECTION. USE ACORN STYLE CLAMPS. |