Permit: T02EL00802

Parcel: 115022780


Addresses:

227 E LINDEN ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE RELOCATION

Date Description Inspector Results Comments
06/18/2002 ELECTRIC - SERVICE RELOCATION Approved
05/21/2002 ELECTRIC - SERVICE RELOCATION Denied IVRS - Inspection 0999*1.) #8 GROUND WIRE TOO SMALL USE #4 COPPER 2.) THE ACORN CLAMPS USED ON GROUND RODS CAN ONLY HAVE ONE CONDUCTOR GOING THUR IT AT THE V SIDE. 3.) NEUTRAL AT WEATHER HEAD TO BE TAPED WHITE 6" OUT OF WEATHER HEAD. 4. PANEL BREAKER COVER MISSING INSTALL SNAP IN 5.) CHASE NIPPLES USED CLOSED NIPPLES 6.) SCREWS ON PANEL COVER MISSING. 7.) AT J-BOX USE CLOSED NIPPLE WITH TWO LOCK NUTS, FROM LB TO J-BOX 8.) NAIL SHOTS USED TO HOLD BOARD INSUFFICIENT, ALSO UNISTRUT LOOSE 1" EMT STRAP LOOSE. 9. ) J-BOX TO BE GROUNDED ALL METAL ENCLOUSRES HAVE TO BE SINCE THIS HOUSE IS UN-OCCUPIED THE STATE OF ARIZ REGISTER REQUIRES A C-11 LICENSED ELECTRICAN TO DO THIS WORK. PLEASE OBTAIN ONE AND ON RECALL LEAVE NAME AND PHONE # TO VERIFY.