Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/01/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*OK TO CLEAR. |
| 04/05/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245* NOTES STILL NO COMPLIANCE WIHT ITEM #2, #4 GROUND WIRE IS STILL STICKING UP 2" ABOVE GROUND. TRIP HAZARD. A REINSPECTION FEE IS ASSESED AS THIS IS THIRD INSPECTION FOR THE SMAE VIOLATION. |
| 04/04/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*NO COMPLIANCE WITH ITEMS #2 & 3. |
| 03/29/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0245*NOTES: 1. INSTALL BOND BUSHINGS WHERE USING CONCENTRIC OK'S WITH REDUCING WASHERS. 250-94 N.E.C. 2. PLEASE BURY # 4 BARE TO GROUND RODS & DRIVE GRND RODS FLUSH WITH GROUND LEVEL (TRIP HAZARD). 3. LB COVER MISSING 4. HOW DID YOU TIE IN CONDUCTORS BEHIND ATTIC VENT? |