Permit: T02EL00606

Parcel: 106071590

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/28/2002 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*
03/26/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*1.) WE HAVE GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM. 2.) THE CORRECT SIZED PLATE IS TO BE USED FOR DRYER RECEPTACLE. 3.) A PLUMBING PERMIT IS NEEDED FOR INSPECTION OF WATER HEATER INSTALLATION. 4.) SUPPORT CONDUITS AT PANEL AS PER CODE 348 5.) AN APPROVED FITTING ARE NEEDED FOR CONNECTIONS TO LB'S CHASE NIPPLES AND CUT UP FITTINGS ARE NOT APPROVED. 6.) SMOKE DETECTOR NEED TO BE 18" FROM CORNER. 7.) WIRLPOOL TUB SWITCH TO BE ON IT'S OWN GFI CIRCUIT AND SEALED FROM WATER TUB NEEDED ACCESS TO PUMP MOTOR. 8.) PLEASE GROUND BATH BARS. 9.) OLD PANEL IN CLOSET FIL UNUSED OPENING.10.) A LICENSED ELECTRICAL CONTRACTOR TO PREFORM WORK AT THIS JOB.