Permit: T02EL00483

Parcel: 119210920


Addresses:

1641 W CIRCLE A DR

Inspection Status: Denied

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/14/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999* 1.) NO GAS PIPING AVAILABLE FOR RANGE. OR ELECTRIC. 2.) INSTALL GFCI PROTECTION FOR KITCHEN COUNTER RECEPTS. 3.) OPEN JUNCTION BOXS WITH WIRING MUST BE COVERED 4.) BROKEN RECEPTACLE (S),IMPROPER WIRING METHODS 5.) USING GROUNDING TYPE RECEPTACLE IN UNGROUNDED SYSTEM. 6.) NEW WIRING/ADDITION. MUST SUBMIT ALL INSPECITON APPROVALS OR HAVE AN CITY APPROVED PLAN FOR GEN INSP.7.) INSTALL ALL SMOKE DETECTORS 9" BELOW CEILING AND 3FT AWAY FROM SUPPLY GRILL. 8.) IMPROPER OVER CURRENT PROTECTION AT SERVICE, NEED KNOCK OUT SEAL, NEED A NEW GROUNDING ELECTRICAL SYSTEM.
03/12/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0920*
03/08/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0920* GATES LOCKED NEED ACCESS INTO HOUSE, HOUSE TO BE UNLOCKED OR MEET INSPECTOR TO UNLOCK. RE CALL INSPECTION.