Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
03/06/2002 ELECTRIC - RECONNECT Approved OK TO CLEAR RECONNECT
03/01/2002 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*1.) SERVICE PANEL COVER HAS TO BE FIXTED SO IT STAYS ON AND OPENS ON HINSES. 2.) USE BREAKER SLOT COVERS ON UNUSED SPACES 3.) SCREW DEAD FRONT COVER INTO REPLACE. 4.) REPAIR O/S CORNER LIGHT AT REAR PORCH. 5.) PANEL AT GARAGE WIRED INCORRECLTY, GROUNDS & NEUTRALS MIXED, NO GROUNDING SYSTEM, ROMEX BELOW 8' DOUBLE LUGGING NEED CONNECTORS TO ENTER PNL, PLUMBING FITTINGS, OPEN SPLICES IN GARAGE, OUTSIDE NEEDS COVER ON RECEPTACLE.